3.6-5kW Series Hybrid Inverter

The primary function of an on-grid inverter is to transform DC electricity produced by solar panels into AC electricity that can be utilized. Hybrid inverters enhance this process by also collaborating with batteries to preserve any surplus energy.

In regions where the electrical infrastructure is underdeveloped or unreliable, or in cases where there is no access to grid power at all, hybrid inverters become increasingly essential.

Specifications
 ModelLF-H3600TL LF-H4600TL LF-H5000TL
 Battery Data
 Battery TypeLithium /Lead-Acid Lithium /Lead-Acid Lithium /Lead-Acid
 Nominal Battery Voltage (V)51.251.251.2
 Battery Voltage Range (V)41.6~58.541.6~58.541.6~58.5
 Max.Continuous Charging Current (A)809595
 Max.Continuous Discharging Current (A)85100100
 Max.Charge Power (W)360046005000
 Max.Discharge Power (W)3600 4600 5000
 PV String Input Data
 Max.Input Power (W)520066007000
 Max.Input Voltage (V)500500500
 MPPT Operating Voltage Range (V)120-430120-430120-430
 Start-up Voltage (V)150150150
 Nominal Input Voltage (V)360360360
 Max.Input Current per MPPT (A)15 15 15
 Max.Short Circuit Current per MPPT (A)18.918.918.9
Number of MPP Trackers222
 Number of Strings per MPPT111
 AC Output Data (On-grid)
 Rated Power Output to Utility Grid (W)360046005000
 Max.Apparent Power Output to Utility Grid (VA)           396046005500
 Max.Apparent Power from Utility Grid (VA)3960 4600 5500
 Nominal Output Voltage (V’220/230/240 220/230/240 220/230/240
 Nominal AC Grid Frequency(Hz)50/60 50/60 50/60
 Max.AC Current Output to Utility Grid (A)17.220.023.9
 Max.AC Current From Utility Grid (A)17.220.023.9
 Max.Total Harmonic Distortion<3% ∠3% <3%
 Power Factor (cos φ)~0.99 (Adjustable from 0.8 leading to 0.8 lagging)
Switch Time<10 ms               <10 ms               <10 ms
 AC Output Data (Back-up)
 Back-up Rated Power (W)360045004500
 Max.Output Apparent Power (VA)3600 4500 4500
 Max.Output Current (A)15.62020
 Nominal Output Voltage (V)220/230/240 220/230/240 220/230/240
 Nominal Output Freqency(Hz)50/60 50/60 50/60
 Output THDv(@Linear Load)<3%<3%<3%
 Conversion Efficiency
 Max.Efficiency97.8%97.8%97.8%
 EU Ffficiency97% 97% 97%
 Max.Battery to AC Efficiency95%95%95%
 MPPT Efficiency99.9%99.9%99.9%
Protection
 Residual Current MonitoringIntegrated Integrated Integrated
 Anti-islanding ProtectionIntegrated Integrated Integrated
Remote ShutdownIntegrated Integrated Integrated
Protection LevelIP65IP65IP65
 Environmental/Ambient Conditions
 Operating Temperature Range (C)-25~+60 -25~+60 -25~+60
 Relative Humidity0 to 95 %,non-condensing
Installation Altitude above Sea Levelup to 2000 m above sea level
 Cooling MethodNatural Cooling Natural Cooling Natural Cooling
 Monitoring SettingsIntegrated data logger
Other Data
Dimensions        (W×H×Dmm)350x580x230350x580x230350x580x230
 Weight (kg)25±0.525±0.525±0.5
 Installation TypeWall Installation with Wall Bracket
CommunicationCAN/RS485/WiFi CAN/RS485/WiFiCAN/RS485/WiFi
 Manufacturer’s Warranty5 Years5 Years5 Years
Product Tags:


    Leave A Message